ADS-SHR-DOC-SPECTECH
  • UiTM/W1/PER/SHR/B/0725/0004
  • CADANGAN MEMBEKAL,MENGHANTAR DAN MENGUJILARI PERALATAN MAKMAL KE FAKULTI KEJURUTERAAN ELEKTRIK UiTM CAWANGAN SARAWAK,KAMPUS SAMARAHAN
  • Oscilloscope
  • 2 Channel 100 MHz Digital Oscilloscope
  • 16 Unit

Maklumat Spesifikasi Teknikal

  
Keterangan Calit Tawaran/Catatan
1. General -
I.
  • Bandwidth: 100 MHz
  • Channels: 2-channel
  • Sample Rate: 1 GS/s sample rate on all channels
  • Record Length: 20k point record length on all channels
Ya

Tidak
II.
  • Advanced triggers include pulse, runt, and line triggers
  • 7-inch WVGA color display with 15 horizontal divisions that shows 50% more signal
  • 32 automated measurements
  • Dual window FFT with simultaneous time and frequency domain views
  • Trigger frequency counter
  • Pan and Zoom capability
  • Multi-language user interface with support for 10 languages in the user interface and front panel overlay
  • Small footprint and light weight
  • Fanless design contributes to low noise operation
Ya

Tidak
III.
  • USB 2.0 host port on the front panel for quick and easy data storage.
  • USB 2.0 device port on rear panel to connect to a PC and remotely control the instrument
  • Probe Compensator: Amplitude 5 V & Frequency 1 KHz
  • Provides helpful on-screen tips for users
  • Built-in oscilloscope handbook provides operating instructions and oscilloscope fundamentals
  • Integrated courseware feature provides lab exercise guidance on the display
  • Autoset, Cursors, and Automated measurements can be disabled to help educators to teach basic concepts to students
Ya

Tidak
2. Vertical system -
I.
  • Vertical resolution: 8 bits
  • Input sensitivity range: 1 mV/div to 10 V/div max. in 1-2-5 sequence with probe attenuation set to 1X
  • DC gain accuracy: ±3.0 % step gain, derated at 0.1 %/°C above 30 °C
  • Maximum Input Voltage: 300 VRMS, Installation Category II; derate above 4 MHz at 20 dB per decade to 200 MHz
  • Offset range: 1 mV/div to 50 mV/div: ± 1 V, 100 mV/div to 500 mV/div: ± 10 V, 1 V/div to 5 V/div : ± 100 V
  • Bandwidth limit: 20 MHz (Typ)
  • Input coupling: DC, AC
  • Input impedance: 1 M ohm ±2 % in parallel with 14 pF ±2 pF
  • Vertical zoom: Vertically expand or compress a live or stopped waveform
  • Peak Detect: Captures glitches as narrow as 4 nsec at all sweep speeds.
  • Average: From 2 to 256 waveforms included in average.
  • Hi-Resolution: Averages multiple sample of one acquisition interval into one waveform point.
  • Roll: Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms/div
Ya

Tidak
3. Horizontal system -
I.
  • Timebase accuracy: ±25 x 10-6 over any >1 ms interval
  • Timebase range: 2 ns/div to 100 sec/div in a 1-2-4 sequence
  • Horizontal zoom: Horizontally expand or compress a live or stopped waveform
  • Deskew range: ± 100 nsec
Ya

Tidak
4. Trigger system -
I.
  • External trigger input: Included
  • Trigger modes: Auto, Normal, Single Sequence
  • Trigger Types (Edge): Positive or negative slope on any channel. Coupling includes DC, HF reject, LF reject, and noise reject.
  • Trigger Types (Pulse Width): Trigger on width of positive or negative pulses that are >, <, =, or ≠ a specified period of time.
  • Trigger Types (Runt): Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again
  • Trigger source: CH1, CH2, AUX IN, AC Line
  • Trigger Coupling: DC, Noise Reject, High Frequency Reject, Low Frequency Reject
  • Trigger signal frequency readout: Provides a frequency readout of the trigger source up to instrument bandwidth
Ya

Tidak
5. Waveform measurements -
I.
  • Cursors: Time, Amplitude, Screen
  • Automated measurements: 32, of which up to six can be displayed on-screen at any one time. Measurements include: Period, Frequency, Rise Time, Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase,
  • Positive Overshoot, Negative Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle
  • RMS, Positive Pulse Count, Negative Pulse Count, Rising Edge Count, Falling Edge Count, Area, Cycle Area, Delay FR,
  • Delay FF, Delay FR, and Delay RR.
  • Gating: Isolate the specific occurrence within an acquisition to take measurements on, using either the screen, between waveform cursors or full record length
Ya

Tidak
6. Waveform math -
I.
  • Arithmetic: Add, Subtract, and Multiply waveforms
  • FFT: Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming,
  • Hanning, or Blackman-Harris.
Ya

Tidak
7. Display system -
I.
  • Display Type: 7-inch TFT Color Display
  • Display Resolution: 800 horizontal by 480 vertical displayed pixels (WVGA)
  • Waveform styles: Vectors, Variable persistence, and Infinite persistence.
  • Format: YT and XY
Ya

Tidak
8. Supplied Accessories -
I.
  • Probe set Per Unit
  • AC Plug Per Unit
Ya

Tidak
9. Manual and Documentation -
I. Original copies of user and operational manual of the equipment must be provided
Ya

Tidak
10. Installation , Testing and Commissioning -
I.
  • Tenderers is required to install and commissioning the proposed equipment in the specified laboratory location in Fakulty Electrical Engineering by their qualified trainers.
  • Installation, testing and commissioning of the entire system should be completed within one month from the delivery date.
Ya

Tidak
11. Training -
I. Tenderers are required to provide training for the use, maintenance and troubleshoot of the equipment to the Technical Staff & Lecture of Electrical Engineering and all training-related costs are borne by the tenderers
Ya

Tidak