1. PROJECT REQUIREMENT
|
-
|
|
|
I. A total number of wireless access point required for this project is 166 Units.
UiTM SABAH
Kampus Kota Kinabalu : 166 Units
|
Ya Tidak
|
|
|
II. The tenderer should ensure all existing network equipment/component/cabling is functioning before and after project implementation. The tenderer shall be responsible for any damage that occurs.
|
Ya Tidak
|
|
|
III. The tenderer must ensure all wireless access point installation and configuration are done by professional engineers. Note: Please attach Engineer Certification and Co-curriculum Vitae (CV). **PLEASE DO NOT DISCLOSE ANY INFORMATION RELATED TO THE COMPANY'S NAME, LOGO, REGISTRATION NUMBER, ETC. THIS INFORMATION MUST BE ERASED AND NOT BE READABLE
|
Ya Tidak
|
|
|
IV. The tenderer is required to perform the installation, testing, and commissioning on-site for the supplied item at the location specified by UiTM
|
Ya Tidak
|
|
|
V. The tenderer shall prepare a complete and comprehensive commissioning report in a form of hardcopy and softcopy after delivery, installation, and testing to ensure the item and accompanying software or the whole package has adhered to the satisfaction of UNIVERSITI TEKNOLOGI MARA before the final acceptance.
|
Ya Tidak
|
|
|
VI. The comprehensive commissioning report must include the User Acceptance Test. The tenderer must also include other additional documents as proof if requested by UiTM.
|
Ya Tidak
|
|
|
VII. The tenderer must affix a sticker on the access point with details such as company name or logo, project number, contact number, and device hostname. The sticker must be durable and long-lasting.
|
Ya Tidak
|
|
|
VIII. The tenderer shall ensure all cable ends and Access points are labeled and the label must be easily read, lasting, and waterproof.
|
Ya Tidak
|
|
|
IX. The tenderer shall ensure the installation of the access point at the optimum level and if the installation of L Bracket is required in a particular location, the tenderer shall provide it.
|
Ya Tidak
|
|
|
X. The tenderer shall supply a padlock for every access point supplied to prevent theft.
|
Ya Tidak
|
|
|
XI. In the event where at a certain location the existing positioning of the access point is not suitable, the tenderer will need to relocate the access point to a better spot.
|
Ya Tidak
|
|
|
XII. The tenderer MUST provide a genuine product. The tenderer must be supported back-to-back by a principal (manufacturer) to provide maintenance services for equipment supplied. The tenderer should attach a Letter of Authorization (LOA) from Distributors/ Principal
** PLEASE DO NOT DISCLOSE COMPANY INFORMATION BY ERASING THE INFORMATION RELATED TO THE COMPANY (NAME, LOGO, REGISTRATION NUMBER, ETC)
|
Ya Tidak
|
|
|
X. Heat Map Analysis
|
-
|
|
|
A ) Installation, testing, heatmap and commissioning MUST be include for access point relocation and mounting
|
Ya Tidak
|
|
|
B ) Tenderer must provide the heat map analysis before doing installation for wireless access point
|
Ya Tidak
|
|
|
C ) Heat map analysis must present to UiTM before the installation wireless access point being done
|
Ya Tidak
|
|
|
D ) The propose location of wireless access point based on heat map analysis must be agree by UiTM
|
Ya Tidak
|
|
|
E ) All documents, design and heat map data during analysis must be presented to UiTM and being documented in hardcopy and softcopy
|
Ya Tidak
|
|
|
2. PRODUCT REQUIREMENT
|
-
|
|
|
I. The Wireless Access Point shall support at least WiFi 6 - Dual radios concurrent, 5GHz 802.11ax 4x4 MIMO is back-wards compatible with 802.11 ac/a/b/g/n client devices
|
Ya Tidak
|
|
|
III. The Access Point support 20, 40 and 80 MHz channels capabilities
|
Ya Tidak
|
|
|
IV. The Wireless Access Point can s upport at least 1 X 2500/1000/100/10Mbps Ethernet Ports (MultiGig)
|
Ya Tidak
|
|
|
V. The Wireless Access Point MUST support 802.3af PoE/802.3at PoE+ IEEE 802.11e Compliant Source 12VDC /1.5A Power Adapter
|
Ya Tidak
|
|
|
VI. The Wireless Access Point can support fast roaming features to ensure connection to the internet is not interrupt.
|
Ya Tidak
|
|
|
VII. The Wireless Access Point MUST come with QR Code features for easy registration thru Mobile Apps
|
Ya Tidak
|
|
|
VIII. The Wireless Access Point can support multiple SSID and BSSID. Each 2.4GHz and 5GHz can support at least 8 SSID and BSSID.
|
Ya Tidak
|
|
|
IX. The Access Point support at least Qualcomm Chipset for better performance
|
Ya Tidak
|
|
|
XIV. The Access Point shall support radio technology as per below:
|
-
|
|
|
A ) Support WiFi networking standard with 802.11ax/ac/a/b/g/n
|
Ya Tidak
|
|
|
B ) Support with 802.11b Direct-sequencespread-spectrum(DSS)
|
Ya Tidak
|
|
|
C ) Support with 802.11ac/a/g/n Orthogonal frequency-division multiplexing (OFDM)
|
Ya Tidak
|
|
|
D ) Support with 802.11ax Orthogonal Frequency Division Multiple Access (OFDMA) and also support MU-MIMO
|
Ya Tidak
|
|
|
XVI. The Wireless Access Point support at least 8 x 3dBi High-Gain, Integrated Omni-Directional Type Antennas. Each 2.4GHz and 5GHz gain 4x3.0dBi and 4x3.0dBi
|
Ya Tidak
|
|
|
XVII. The Wireless Access Point support the list of wireless security as below:
|
-
|
|
|
|
Ya Tidak
|
|
|
B ) WPA2-Enterprise (AES)
|
Ya Tidak
|
|
|
|
Ya Tidak
|
|
|
|
Ya Tidak
|
|
|
|
Ya Tidak
|
|
|
F ) Wireless STA (Client) Connected List
|
Ya Tidak
|
|
|
|
Ya Tidak
|
|
|
H ) Client Isolation
|
Ya Tidak
|
|
|
I ) MAC Adress Filtering, up to 32 MACs per SSID
|
Ya Tidak
|
|
|
XXI. The Wireless Access Point can support LED Blinking function easy troubleshooting.
|
Ya Tidak
|
|
|
XXIV. The Wireless Access Point can support Dynamic Channel Selection to monitor traffic and noise levels on the channel
|
Ya Tidak
|
|
|
XXVII. The Wireless Access Point come with features Traffic Shaping Controls that can control the user bandwidth
|
Ya Tidak
|
|
|
XXXII. The Wireless Access Point MUST compatible with the cloud controller access that come together with access point for access point manager with no additional cost to UiTM.
|
Ya Tidak
|
|
|
3. WIRELESS CLOUD CONTROLLER
|
-
|
|
|
I. Support Artificial Intelligence (AI) Driven Engine Wireless Controller
|
Ya Tidak
|
|
|
II. Controller Host as Serverless Architecture (Function as a Service) with each function has its own scalability and works together seamlessly
|
Ya Tidak
|
|
|
III. Multisite and Location Plot on Google Map for AP / Switch Management
|
Ya Tidak
|
|
|
|
Ya Tidak
|
|
|
|
Ya Tidak
|
|
|
|
Ya Tidak
|
|
|
C ) Hierarchy View
|
Ya Tidak
|
|
|
VI. License FREE Layer 7 Application Awareness as Monitoring Tools (YouTube, Facebook, Dropbox and etc)
|
Ya Tidak
|
|
|
VII. Able to track user route location and AP location, with aggregates and analyzes activities of a specific wireless client to provide an intuitive and historical view
|
Ya Tidak
|
|
|
VIII. Able to detect interference source, time of Interference, source of interference with the channel utilization
|
Ya Tidak
|
|
|
IX. Able to check AP Real Time including CPU, Memory and Throughput as monitoring
|
Ya Tidak
|
|
|
X. Support 1 click push config from faulty unit (AP / Switch) to new replacement unit
|
Ya Tidak
|
|
|
XI. Block Suspicious Clients from Network with rogue client monitoring tools
|
Ya Tidak
|
|
|
XII. Support TFA Secured Tunnel for Security Log in
|
Ya Tidak
|
|
|
XIII. Support Facebook WIFI Authentication thru Controller, including Log in Via Instagram
|
Ya Tidak
|
|
|
XIV. Controller must come with AI-Driven Advisory Board
|
Ya Tidak
|
|
|
XV. Exposure Analysis to show the timeline with the list of clients connected to the same AP based on a particular client (For Covid19 close contact tracking)
|
Ya Tidak
|
|
|
XVI. Controller must come with support Passcode, which is used to verify users identities for security purposes for Remote Support
|
Ya Tidak
|
|
|
XVII. Floor plans to simulate the heat map, which draw the obstacles is the must to have accuracy of the coverage
|
Ya Tidak
|
|
|
XVIII. Virtual AP to simulate the heatmap if adding more AP to increase the coverage
|
Ya Tidak
|
|
|
XIX. Support Reporting function with send to recipients by email and schedule to run periodically.
|
Ya Tidak
|
|
|
XX. Network topology with graphic overview of the logical network topology and the status of the devices
|
Ya Tidak
|
|
|
XXI. Mobile Apps Monitoring
|
Ya Tidak
|
|
|
XXII. Support Picture upload to management portal for AP / Switch mounting location is a must.
|
Ya Tidak
|
|
|
XXIII. Controller must come with backup and restore to protect the configuration.
|
Ya Tidak
|
|
|
XXIV. Controller come with Intercom function for remote support
|
Ya Tidak
|
|
|
XXV. Supported Dynamic VLAN
|
Ya Tidak
|
|
|
XXVI. Notification via Email and Mobile
|
Ya Tidak
|
|
|
XXVII. Supported Splash Page with html is additional advantage
|
Ya Tidak
|
|
|
XXVIII. SSID Scheduling to limit the time of SSID broadcast.
|
Ya Tidak
|
|
|
XXIX. Support Dynamic Channel Selection to monitor traffic and noise levels on the channel
|
Ya Tidak
|
|
|
XXX. Schedule Firmware Upgrade
|
Ya Tidak
|
|
|
XXXI. Trial Zone Firmware upgrade (Before upgrade to latest version)
|
Ya Tidak
|
|
|
XXXII. VIP List via mac address to bypass Captive Portal
|
Ya Tidak
|
|
|
XXXIII. Real-time information of port connection states and PoE utilization and make port configurations for individual switches.
|
Ya Tidak
|
|
|
XXXIV. Multi-Role Privileges
There are 3 basic user roles:
|
Ya Tidak
|
|
|
A ) Full access privileges
|
Ya Tidak
|
|
|
B ) Read-only privileges
|
Ya Tidak
|
|
|
C ) Front Desk priviledges
|
Ya Tidak
|
|
|
XXXV. Various authentication methods:
|
Ya Tidak
|
|
|
A ) Cloud Users
|
Ya Tidak
|
|
|
B ) Mypsk Users
|
Ya Tidak
|
|
|
C ) Voucher ervices
|
Ya Tidak
|
|
|
D ) Facebook Wifi
|
Ya Tidak
|
|
|
E ) Active Directory
|
Ya Tidak
|
|
|
F ) Google LDAP
|
Ya Tidak
|
|
|
G ) my LDAP Server
|
Ya Tidak
|
|
|
XXXV. Support Limited Life time Warranty
|
Ya Tidak
|
|
|
4. POWER OPTIONS
|
-
|
|
|
I. The Access Point should support input power requirement such as 802.3at PoE+ power injector
|
Ya Tidak
|
|
|
II. The Access Point should support powering options such as
|
Ya Tidak
|
|
|
|
Ya Tidak
|
|
|
|
Ya Tidak
|
|
|
|
Ya Tidak
|
|
|
D ) Power Injector
|
Ya Tidak
|
|
|
5. TECHNICAL/OPERATING MANUAL, ENGINEERING SERVICES AND OTHER ACCESSORIES
|
-
|
|
|
I. User operating/technical manual must be provided by the tenderer.
|
Ya Tidak
|
|
|
II. All necessary adapters, cables and other accessories required shall be provided.
|
Ya Tidak
|
|
|
III. Tenderers should provide Power injector for any Wireless Access Point that is not connected to PoE Switch.
|
Ya Tidak
|
|
|
IV. All other related software, systems, material, components, cabling and other accessories which are required to ensure full
operation and integration with new or existing equipment of the item must be provide by the tenderer.
|
Ya Tidak
|
|
|
6. CATALOGUES/BROCHURES
|
-
|
|
|
I. All related catalogue/brochure shall be provided by the tenderer
|
Ya Tidak
|
|
|
7. WARRANTY
|
-
|
|
|
I. One (1) year of maintenance support consists of faulty equipment replacement (Next Business Day - 8X5XNBD) and software upgrade shall be provided by the tenderer. Please attach the Letter of Warranty (LoW) from the principal.
**PLEASE DO NOT DISCLOSE ANY INFORMATION RELATED TO THE COMPANY'S NAME, LOGO, REGISTRATION NUMBER, ETC. THIS INFORMATION MUST BE ERASED AND NOT BE READABLE
|
Ya Tidak
|
|
|
II. The tenderer shall ensure the Access Point Support Limited Lifetime Warranty that provides full warranty coverage of the hardware for as long as the original end-user continues to own or use the product.
|
Ya Tidak
|
|
|
III. The tenderer shall be responsible for the installation, test-run and commissioning of the equipment and accompanying
software to the satisfaction of UNIVERSITI TEKNOLOGI MARA before final acceptance. All costs on installation,
commissioning and Test run shall be borne by tenderer during the warranty period.
|
Ya Tidak
|
|
|
IV. Maintenance support is needed during and after the warranty period. Tenderers must provide details of addresses of
locations of after sales service centers that shall be responsible for maintenance work for these items during the warranty
period.
|
Ya Tidak
|
|
|
V. Free support through fax, email, telephone must be provided during the warranty period.
|
Ya Tidak
|
|
|
VI. A maximum of 4 hours response time to attend to problem call on breakdown of equipment or component is to abide by
the tenderer.
|
Ya Tidak
|
|
|
8. DELIVERY PERIOD
|
-
|
|
|
I. Delivery period must be within 18 weeks after tenderer has received the Local Order.
|
Ya Tidak
|
|
|
II. If there is a delay in project delivery, Tenderer must apply for extension at least 1 month before the delivery period ends.
|
Ya Tidak
|
|