1. GENERAL REQUIREMENTS -
I. Vendors must comply with all the requirements specified in this tender document
Ya

Tidak
II. Vendors must bear all costs of supplying the specified quantity of items to UiTM. Such costs shall include the costs of delivery, installation, commissioning, training, troubleshoot and maintenance work (including parts labour and on-site service) within the specified warranty period
Ya

Tidak
III. Vendors must bear all costs of supplying the specified quantity of items to UiTM. Such costs shall include
the costs of delivery, installation, commissioning, troubleshoot and maintenance work (including parts,
labour and on-site service) within the specified warranty period
The Workstations will be distributed in the following Campuses:
1. Electrical Engineering School, College of Engineering, UiTM Shah Alam Selangor x 1 Sets
2. UiTM Penang Branch, Permatang Pauh Campus x 1 Sets
Ya

Tidak
2. SPECIFICATION -
I. OVERVIEW
An analog tester designed for parallel testing of various devices, including analog devices, at the channel level. It's a multisite solution that allows for independent testing of multiple sites with high parallel efficiency, particularly for quad-site and octal-site configurations.
Ya

Tidak
II. GENERAL:
- an analog/linear test system designed based on PXIe platform
- Scalability and modularity inherited from PXIe platform
- Turn-key test solution
- Comes with efficient techFlow development and production software
- Test development and test code conversion services available
- Seamless transition from test development, bench characterization to production
- Multiple independent techFlow running on the same system
- Up to 85% quad-site efficiency
- Mainframe: 605mm (w) x 790mm (d) x 1400mm (h)
- Requires a temperature range of 23±5°C.
Ya

Tidak
III. KEY SPECIFICATIONS:
- Equipped with 24 digital channels and 1 SMU channels
Architecture:
-
Built on a PXI (PCI eXtensions for Instrumentation) chassis, allowing users to customize and expand the system based on testing requirements.
- Enables seamless integration with other PXI-compatible instruments.

High Parallel Test Efficiency:
-
Supports parallel and index-paralles testing, maximizing test throughput and minimizing
- Capable up to 8 test sites per chassis, maintaining high performance across all channels

Analog & mixed-signal testing
Designed to test a wide array of devices:
- PMICs (Power Management ICs)
- ADCs (Analog-to-Digital Converters)
- LDOs (Low Dropout Regulators)
- LEDs and Smart RGB LEDs
- Sensors and Regulators

TechFlowâ„¢ Test Executive Software
Companys’ proprietary software suite for:
- Device test program development
- Real-time debugging
- Data logging and statistical analysis
Provides intuitive GUI, scripting tools, and modular test libraries.

Advanced Triggering and Communication
- External trigger input/output for synchronization with handler/prober systems.
- Supports MIPI interfaces for high-speed data communication.
Ya

Tidak
IV. Flexible Integration
- Can operate in multi-chassis configurations, enabling large-scale testing scenarios.
- Compatible with other industry-standard platforms and interfaces.

Low Maintenance & Ease of Use
- User-replaceable cards/modules for easy service.
- Compact form factors ideal for space-constrained lab or production environments.
Ya

Tidak
V. ELECTRICAL SPECIFICATIONS:
SMU Module - Voltage Programming and Measurement Accuracy

Range: 1 V (min)
± (% of Voltage + Offset), Tcal ± 5 °C: 0.05 % + 1 mV

Range: 48 V (max)
± (% of Voltage + Offset), Tcal ± 5 °C: 0.015 % + 7.2 mV
Ya

Tidak
VI. SMU Module - Current Programming and Measurement Accuracy

Range: 1 uA (min)
± (% of Current + Offset), Tcal ± 5 °C: 0.1% + 1 nA

Range: 3 A (max)
± (% of Current + Offset), Tcal ± 5 °C: 0.12% + 3 mA

Range: 10 A (pulse)
± (% of Current + Offset), Tcal ± 5 °C: 0.5% + 50mA, typical
Ya

Tidak
VII. Digital Module - PPMU
1) Force voltage (FV)
Range: -2.5V to 10.5V
Accuracy: 0.1% of value + 10.5mV
Ya

Tidak
VIII. 2) Force current (FI)
Range: 2uA, 8uA, 32uA, 128uA, 512uA, 2mA, 8mA, 32mA
Accuracy: 0.25% of value + 0.25% of range
Ya

Tidak
IX. 3) Measure voltage
Range: -2.5V to 10.5V
Accuracy: 0.1% of value + 10.5mV
Ya

Tidak
X. 4) Measure current
Range: 2uA, 8uA, 32uA, 128uA, 512uA, 2mA, 8mA, 2uA
Accuracy: 0.25% of value + 0.25% of range
Ya

Tidak
XI. CONFIGURED WITH:
-The Tester for Logic (Single Site) equipped with 24 digital channels and 1 SMU channels
DC Hardware Subsystem
- 18 Slots PXIe Chassis with Controller
- Mid Power SMU Module
- High Speed Digital Module
Ya

Tidak
XII. Platform Subsystem (Upgrade)
- Performance PC with Half Test Rack
- Test Head Board
- Cable and Accessories
Ya

Tidak
XIII. INCLUDE WITH:
Customized education KIT for logic

- Load board design
- Load board fabrication & assembly
- Socket & Manual actuator
- Test device
Ya

Tidak
XIV. Software subsystem ( per tester)
1) Test Executive Software
- techFlow software
- company production system
2) Education Lab PC techflow License
3) Extend Education Lab PC techFlow License
Ya

Tidak
XV. Education syllabus module
- Logic Test Lectures Training & Materials
Ya

Tidak
XVI. Maintenance Service Contract - 4 years
- Tester for logic Hardware Calibration
- Tester for logic Hardware Repair
- 1-1 Module Loaner upon Calibration/Repair
- Support Test Program Update & Maintenance
- Within 48 hours Onsite Support
Ya

Tidak
XVII. SUPPLIED ACCESSORIES:
- Half test rack
- Cable and accessories
- AC plugs
- AC power cord (13 ft. / 4m)
Ya

Tidak
3. CATALOGUES / BROCHURES -
I. Vendors must provide the catalogues / brochures / technical specification manuals with the tender proposal
Ya

Tidak
II. Original copies of user and operational manual of the equipment must be provided
Ya

Tidak
4. TRAINING -
I. Tenderers are required to provide training for the use, maintenance and troubleshoot of the equipment to the Technical Staff & Lecture of Electrical Engineering School, College of Engineering, UiTM Shah Alam and all training-related costs are borne by the tenderers.
Ya

Tidak
II. A minimum of one (1) day training for a minimum of one (1) participants covering each module. (Vendors must provide details/syllabus of the training module)
Ya

Tidak
III. Complete training materials and documentation must be provided to all participants
Ya

Tidak
IV. The training MUST be conducted by trainers who are certified by principal. Please attach the trainer's certification that is certified by principal supplier.
Ya

Tidak
V. Certificate of attendance must be provided
Ya

Tidak
VI. Training sessions must be conducted at the following Campuses:
1. School of Electrical Engineering, College of Engineering, UiTM Shah Alam Selangor
2. UiTM Penang Branch, Permatang Pauh Campus
Ya

Tidak
5. WARRANTY AND SUPPORT -
I. Vendors must have local service for repair services and provide on call services when required by UiTM
Ya

Tidak
II. Vendors must provide details of warranty. INCLUDING ALL parts, labour, basic phone support for hardware issue, repairs onsite). Please attach the Letter of Warranty (LOW) from the principle, which states that UiTM is entitled to 4 years of warranty upon project completion
Ya

Tidak
III. Vendors be responsible for the installation, commissioning and test-run of the equipment and accompanying software (if applicable) to the satisfaction of UNIVERSITI TEKNOLOGI MARA before final acceptance.
Ya

Tidak
IV. All cost on delivery. installation, commissioning and test run shall be borne by the vendor.
Ya

Tidak
V. The vendors MUST provide a genuine product. The vendors must be supported back-to-back by a principle (manufacturer) to provide maintenance services for equipment supplied. The vendors should attach a Letter of Authorization (LOA) from Distributors/ Principal.
Ya

Tidak
VI. Free support through fax, email, telephone must be provided during the warranty period
Ya

Tidak
6. OTHER REQUIREMENTS -
I. Note that all other related material, components and cabling, which are required to ensure full operation of the above package must be supplied and borne by vendors
Ya

Tidak