1. GENERAL REQUIREMENT
|
-
|
|
|
I. The scope of this project is to deliver, install and configure, testing and commissioning 24 port Access Switch.
|
Ya Tidak
|
|
|
II. The tenderer needs to propose the optimum specification for the equipment to function and integrate well with the existing system. Should any component that need to be added shall be proposed by the tenderer.
|
Ya Tidak
|
|
|
III. The proposed item must be NEW and not refurbished or OEM.
|
Ya Tidak
|
|
|
IV. The tenderer MUST ensure the availability, operability, reliability and functionality of the supplied item components to function properly.
|
Ya Tidak
|
|
|
V. All other related material, components or equipment, software and cabling are not specified but are required to ensure full integration of above item with proposed system requirements/application must be provided by the tenderer without any cost to UiTM.
|
Ya Tidak
|
|
|
VI. The tenderer must ensure that the access switch offered meets the characteristics or exceeds the required specifications. **Please specify the exact model offered in the tender document.
|
Ya Tidak
|
|
|
VII. The tenderer shall include dismantle work for existing / old network switch.
|
Ya Tidak
|
|
|
VIII. The delivery period must be within 18 weeks after the tenderer has received the offer letter from UiTM.
|
Ya Tidak
|
|
|
IX. If there is a delay in project delivery, the tenderer must apply for an extension at least 1 month before the delivery period ends.
|
Ya Tidak
|
|
|
X. ANY DOCUMENTS PRESENTED OR SUBMITTED BY THE TENDERER IN THIS DOKUMEN TEKNIKAL MUST NOT DISCLOSE ANY INFORMATION RELATED TO THE COMPANY’S NAME, LOGO, REGISTRATION NUMBER, ETC. THIS INFORMATION MUST BE ERASED AND NOT BE READABLE.
|
Ya Tidak
|
|
|
2. TECHNICAL REQUIREMENT
|
-
|
|
|
I. The switch MUST support Cloud Managed 24-Port Multi-Gigabit 410W
|
Ya Tidak
|
|
|
II. The switch supports PoE + access ports.
|
Ya Tidak
|
|
|
III. The Access switch support at least 4 x 10G SFP+ Ports for uplinks and all port are functioning without needed additional licenses.
|
Ya Tidak
|
|
|
IV. The switch support 24 ports with 802.3af/at POE+
|
Ya Tidak
|
|
|
V. The switch support at least 16 ports 10/100/1000 Mbps and 8 ports 100/1000/2500 Mbps
|
Ya Tidak
|
|
|
VI. Fully support at least 1Gbps access ports and 10Gbps uplink ports.
|
Ya Tidak
|
|
|
VII. The switch MUST support Flash Memory at least 128MB.
|
Ya Tidak
|
|
|
VIII. The switch can support at least 152 Gbps Switching Capacity
|
Ya Tidak
|
|
|
IX. The switch support Vlan from 1-4094 (at least 256 groups)
|
Ya Tidak
|
|
|
X. The switch able to support Mac Address table at least 16K
|
Ya Tidak
|
|
|
XI. The switch can support hybrid switch mode that can supports multiple management options.
|
Ya Tidak
|
|
|
XII. The Access switch support PoE extended mode that allow to deploy the device over Ethernet cable at more extended range up to 250 meters.
|
Ya Tidak
|
|
|
X. The switch can support Jumbo Frame at least 10K
|
Ya Tidak
|
|
|
XIV. The switch support PD lifeguard that real-timely monitors the status of the device and auto reboot the device when it is down.
|
Ya Tidak
|
|
|
XV. The switch can support Voice VLAN for fast and reliable deployment of VoIP
|
Ya Tidak
|
|
|
XVI. The switch can monitor realtime CPU and RAM.
|
Ya Tidak
|
|
|
XVII. The switch has the ability to continuous PoE power supplies the device in operation without interruption of the switch rebooting during switch firmware upgrading.
|
Ya Tidak
|
|
|
XVIII. The switch can support Advanced Topology to monitor the whole network including 3rd-Party Devices.
|
Ya Tidak
|
|
|
XIX. The switch support ONE click push configuration from faulty unit to new replacement unit.
|
Ya Tidak
|
|
|
XX. The switch can support Intelligent Diagnostics.
|
Ya Tidak
|
|
|
XXI. The switch can support Trial Zone Firmware upgrade that give user experience new upgrade before confirm upgrade to latest version.
|
Ya Tidak
|
|
|
XXII. The switch support Port Security with maximum 256 Entries.
|
Ya Tidak
|
|
|
XXIII. The switch must supported Layer 2 features.
|
Ya Tidak
|
|
|
XXIV. The switch support IGMP Snooping and IGMP Multicast Forwarding
|
Ya Tidak
|
|
|
XXV. The switch can support Link Aggregation / port channel.
|
Ya Tidak
|
|
|
XXVI. The switch support advanced Access Control List (ACL) such as MAC Based ACL, IPV4/IPV6 Based ACL, ACL Binding and Time Based ACL.
|
Ya Tidak
|
|
|
3. INSTALLATION, TESTING AND COMMISSIONING
|
-
|
|
|
I. Tenderer shall provide a user operating / technical manual for UiTM referral.
|
Ya Tidak
|
|
|
II. All other related software, systems, material, components, cabling and other accessories which are required to ensure full operation and integration with new or existing equipment of the item must be provided by the tenderer.
|
Ya Tidak
|
|
|
III. The tenderer shall be responsible for the installation, test-run and commissioning of the equipment and accompanying software to the satisfaction of UNIVERSITI TEKNOLOGI MARA before final acceptance.
|
Ya Tidak
|
|
|
IV. All costs on installation, commissioning and test run shall be borne by tenderer during the warranty period.
|
Ya Tidak
|
|
|
V. Tenderer shall proposed all additional or required license to ensure the switch can operate to the optimum.
|
Ya Tidak
|
|
|
VI. Tenderer must document all switches configuration, management IP address and location in hard copy and must be submitted to UiTM.
|
Ya Tidak
|
|
|
VII. Any cost related to installation and configuration shall be borne by the tenderer.
|
Ya Tidak
|
|
|
VIII. Tenderer are required to provide training for the use, maintenance, troubleshoot or similar environment for the item.
|
Ya Tidak
|
|
|
IX. Training should be conducted for three (3) persons of technical staff or more assigned by UiTM.
|
Ya Tidak
|
|
|
X. The duration of training at least one (1) working days (8 hours per day x 1 days= 8 hours).
|
Ya Tidak
|
|
|
XI. The duration / time / training syllabus / number of participants for the training would be discussed on delivery of the equipment
|
Ya Tidak
|
|
|
4. WARRANTY AND TECHNICAL SUPPORT
|
-
|
|
|
I. Minimum of three (3) years of maintenance support consists of equipment faulty replacement (Next Business Day8X5XNBD) and software upgrade shall be provided.
|
Ya Tidak
|
|
|
II. Response time to attend to a problem call breakdown of equipment or component is MAXIMUM 4 hours. The support must be within 8 hours of working days.
|
Ya Tidak
|
|
|
III. The switch shall have warranty for a period from date of installation against defects inmaterials and/or workmanship.
|
Ya Tidak
|
|
|
IV. Tenderer MUST propose and provide a genuine product.
|
Ya Tidak
|
|
|
V. Tenderer must ensure all switches installation and configuration are done by professional engineers.
|
Ya Tidak
|
|
|
VI. Maintenance support is needed during and after the warranty period. Tenderers must provide details of addresses of locations of after sales service centres that shall be responsible for maintenance work for these items during the warranty period.
|
Ya Tidak
|
|
|
VII. Free support through fax, email, telephone must be provided during the warranty period.
|
Ya Tidak
|
|
|
VIII. The successful tenderer must be supported back to back by principal to provide maintenance services for equipment supplied.
|
Ya Tidak
|
|
|
IX. If there is a delay in project delivery, Tenderer must apply for extension at least 1 month before the delivery period ends.
|
Ya Tidak
|
|
|
X. 2 times a year for 2 years of preventive maintenance support consists of equipment faulty Replacement (Next Business Day) and software upgrade shall be provided.
|
Ya Tidak
|
|
|
5. SUPPORTING DOCUMENTS
TENDERER MUST PROVIDE THE FOLLOWING SUPPORTING DOCUMENTS AND MUST BE PRESENTED IN THIS DOKUMEN TEKNIKAL
** PLEASE DO NOT DISCLOSE COMPANY INFORMATION BY ERASING THE INFORMATION RELATED TO COMPANY (NAME, LOGO, REGISTRATION NUMBER, ETC) FOR ALL DOCUMENTS REQUIRED HERE.
|
-
|
|
|
I. The tenderer shall provide all related catalogues/brouchere, and the document must be presented in Dokumen Teknikal
|
Ya Tidak
|
|
|
II. The tenderer must attach a Letter of Authorization (LoW) from Principal. This document must be presented in Dokumen Teknikal.
|
Ya Tidak
|
|
|
III. The tenderer must attach a Letter of Warranty (LoW) from Principal.This document must be presented in Dokumen Teknikal
|
Ya Tidak
|
|
|
IV. The tenderer must attach at least ONE (1) related Engineer certification and Co-curriculum Vitea (CV) upon signing SURAT SETUJU TERIMA (SST).
|
Ya Tidak
|
|