1. GENERAL REQUIREMENTS
|
-
|
|
|
I. Capacity 3KVA
|
Ya Tidak
|
|
|
II. User friendly LCD Display
|
Ya Tidak
|
|
|
III. Converter Mode available
|
Ya Tidak
|
|
|
IV. Comes with USB port, RS232 Port, SNMP slot & Power Management Software
|
Ya Tidak
|
|
|
V. Vendor shall provide Uninterruptible Power Supply (UPS) which is new and not refurbish
|
Ya Tidak
|
|
|
VI. The proposed equipment must have a local services center to provide a full technical support and maintenance
|
Ya Tidak
|
|
|
VII. All related catalogues/brochures shall be provided by the vendor
|
Ya Tidak
|
|
|
VIII. **PLEASE DO NOT DISCLOSE ANY INFORMATION RELATED TO THE COMPANY'S NAME, LOGO, REGISTRATION NUMBER, ETC. THIS INFORMATION MUST BE ERASED AND NOT BE READABLE
Noted : Please refer to UiTM staff for detailed installation location
|
Ya Tidak
|
|
|
2. TECHNICIAL
|
-
|
|
|
I. The proposed equipment must provide comprehensive protection against surges and spikes
|
Ya Tidak
|
|
|
II. Must provide clean and stable power to connected equipment while its embedded microprocessor controller guarantees high reliability
|
Ya Tidak
|
|
|
III. Must provide Green Power Function to achieve lower power consumption for energy saving
|
Ya Tidak
|
|
|
3. ELECTRICAL OUTPUT
|
Ya Tidak
|
|
|
I. Voltage : 220/380 VAC, 230/400 VAC, 240/415 VAC selectable
|
Ya Tidak
|
|
|
II. Frequency: 47- 53Hz or 57- 63Hz
|
Ya Tidak
|
|
|
III. Phase : Single Phase
|
Ya Tidak
|
|
|
IV. Efficiency: 87% - 89% depending on load
|
Ya Tidak
|
|
|
V. Voltage Distortion :
|
Ya Tidak
|
|
|
A ) less than 6% of THD at rate non-linear load
|
Ya Tidak
|
|
|
B ) less than 3% of THD at rate linear load
|
Ya Tidak
|
|
|
4. POWER
|
-
|
|
|
I. Rating: at least 3kVa at pf 0.9
|
Ya Tidak
|
|
|
II. Rating: Double-Conversion Online UPS
|
Ya Tidak
|
|
|
5. ELECTRICAL INPUT
|
-
|
|
|
I. Nominal Voltage : 208/220/230/240VAC
|
Ya Tidak
|
|
|
II. Voltage Range: 110-300VAC at 50% Load, 160-280VAC at 100% Load
|
Ya Tidak
|
|
|
III. Rated Frequency : 40Hz – 70Hz
|
Ya Tidak
|
|
|
IV. Power Factor: greater than 99% at Nominal Voltage (100% Load)
|
Ya Tidak
|
|
|
V. Efficiency = 93% at Online Mode, 91% at Battery Mode.
|
Ya Tidak
|
|
|
6. BATTERY
|
Ya Tidak
|
|
|
I. Type: Sealed, Maintenance-free lead-acid battery
|
Ya Tidak
|
|
|
II. Number of batteries: 9 Ah, 12 V, 6 pcs
|
Ya Tidak
|
|
|
III. Recharge time: 4 hrs to 90% capacity
|
Ya Tidak
|
|
|
IV. Back-up time: 3 minutes at full load
|
Ya Tidak
|
|
|
7. CONTROL FEATURES
|
Ya Tidak
|
|
|
III. User Interface: Monitoring panel with LCD/LED display : UPS on, Line on, Battery operation, Bypass, Audible alarm
|
Ya Tidak
|
|
|
IV. Serial Communications Port: RS232
|
Ya Tidak
|
|
|
8. ENVIRONMENTAL
|
Ya Tidak
|
|
|
I. Ambient Temperature: 0 degree celsius to 40 degree celsius operating
|
Ya Tidak
|
|
|
II. Humidity: 0 to 95% RH non-condensing
|
Ya Tidak
|
|
|
III. Audible Noise: 58 dBA (1M from surface)
|
Ya Tidak
|
|
|
9. PHYSICAL
|
-
|
|
|
I. I Dimension : 63mm x 438mm x 88mm (2u)
|
Ya Tidak
|
|
|
II. At Least Weight : 29.3kg
|
Ya Tidak
|
|
|
III. Type : 2-in-1 Rackmount-Tower (Display can be rotate)
|
Ya Tidak
|
|
|
10. COMMUNICATIONS
|
-
|
|
|
I. SNMP Web-Pro for Manage and Monitor UPS.
|
Ya Tidak
|
|
|
11. TECHNICAL/OPERATING MANUAL, ENGINEERING SERVICES & OTHER ACCESSORIES
|
-
|
|
|
I. User manual/operating manual must be provided by the vendor
|
Ya Tidak
|
|
|
II. All other related material, components and cabling which are not specified but required to ensure full operation must be supplied by the vendor
|
Ya Tidak
|
|
|
12. SUPPORT & WARRANTY
|
-
|
|
|
I. Delivery cost of the equipment is borne by the vendor
|
Ya Tidak
|
|
|
II. Must provide comprehensive and extensive after sales service on labor and overall parts
|
Ya Tidak
|
|
|
III. All other related software, material, components and cabling which are not specified but are required to ensure full integration of the item MUST be provided.
|
Ya Tidak
|
|
|
13. INSTALLATION & TRAINING:
|
-
|
|
|
I. Pre requisite of requirement of installation, testing and commissioning on site for the supplied package and components MUST be done by tenderer
|
Ya Tidak
|
|
|
II. Tendered MUST provide Transfer Technology Session (TOT) training for configuration, operation and maintenance of the system which must cover Rack Mountable Base Unit System Intelligent and UPS Management Software for UiTM's personnel.(Plase specify details of the training by providing
syllabus/guideline).
|
Ya Tidak
|
|
|
III. Minimum of three (3) participants on Server and System Management training session
|
Ya Tidak
|
|
|
IV. Original training materials (hard copy and soft copy) and documentation MUST be provided on the training day.
|
Ya Tidak
|
|
|
V. Delivery and installation at site of server as per instruction of UiTM without incurring any additional costs to UiTM.
|
Ya Tidak
|
|