1. GENERAL REQUIREMENTS -
I. Capacity 3KVA
Ya

Tidak
II. User friendly LCD Display
Ya

Tidak
III. Converter Mode available
Ya

Tidak
IV. Comes with USB port, RS232 Port, SNMP slot & Power Management Software
Ya

Tidak
V. Vendor shall provide Uninterruptible Power Supply (UPS) which is new and not refurbish
Ya

Tidak
VI. The proposed equipment must have a local services center to provide a full technical support and maintenance
Ya

Tidak
VII. All related catalogues/brochures shall be provided by the vendor
Ya

Tidak
VIII. **PLEASE DO NOT DISCLOSE ANY INFORMATION RELATED TO THE COMPANY'S NAME, LOGO, REGISTRATION NUMBER, ETC. THIS INFORMATION MUST BE ERASED AND NOT BE READABLE
Noted : Please refer to UiTM staff for detailed installation location
Ya

Tidak
2. TECHNICIAL -
I. The proposed equipment must provide comprehensive protection against surges and spikes
Ya

Tidak
II. Must provide clean and stable power to connected equipment while its embedded microprocessor controller guarantees high reliability
Ya

Tidak
III. Must provide Green Power Function to achieve lower power consumption for energy saving

Ya

Tidak
3. ELECTRICAL OUTPUT Ya

Tidak
I. Voltage : 220/380 VAC, 230/400 VAC, 240/415 VAC selectable
Ya

Tidak
II. Frequency: 47- 53Hz or 57- 63Hz
Ya

Tidak
III. Phase : Single Phase
Ya

Tidak
IV. Efficiency: 87% - 89% depending on load
Ya

Tidak
V. Voltage Distortion :
Ya

Tidak
A ) less than 6% of THD at rate non-linear load
Ya

Tidak
B ) less than 3% of THD at rate linear load
Ya

Tidak
4. POWER -
I. Rating: at least 3kVa at pf 0.9
Ya

Tidak
II. Rating: Double-Conversion Online UPS
Ya

Tidak
5. ELECTRICAL INPUT -
I. Nominal Voltage : 208/220/230/240VAC
Ya

Tidak
II. Voltage Range: 110-300VAC at 50% Load, 160-280VAC at 100% Load
Ya

Tidak
III. Rated Frequency : 40Hz – 70Hz
Ya

Tidak
IV. Power Factor: greater than 99% at Nominal Voltage (100% Load)
Ya

Tidak
V. Efficiency = 93% at Online Mode, 91% at Battery Mode.
Ya

Tidak
6. BATTERY Ya

Tidak
I. Type: Sealed, Maintenance-free lead-acid battery
Ya

Tidak
II. Number of batteries: 9 Ah, 12 V, 6 pcs
Ya

Tidak
III. Recharge time: 4 hrs to 90% capacity
Ya

Tidak
IV. Back-up time: 3 minutes at full load
Ya

Tidak
7. CONTROL FEATURES Ya

Tidak
III. User Interface: Monitoring panel with LCD/LED display : UPS on, Line on, Battery operation, Bypass, Audible alarm
Ya

Tidak
IV. Serial Communications Port: RS232
Ya

Tidak
8. ENVIRONMENTAL Ya

Tidak
I. Ambient Temperature: 0 degree celsius to 40 degree celsius operating
Ya

Tidak
II. Humidity: 0 to 95% RH non-condensing
Ya

Tidak
III. Audible Noise: 58 dBA (1M from surface)
Ya

Tidak
9. PHYSICAL -
I. I Dimension : 63mm x 438mm x 88mm (2u)












Ya

Tidak
II. At Least Weight : 29.3kg
Ya

Tidak
III. Type : 2-in-1 Rackmount-Tower (Display can be rotate)

Ya

Tidak
10. COMMUNICATIONS -
I. SNMP Web-Pro for Manage and Monitor UPS.

Ya

Tidak
11. TECHNICAL/OPERATING MANUAL, ENGINEERING SERVICES & OTHER ACCESSORIES

-
I. User manual/operating manual must be provided by the vendor
Ya

Tidak
II. All other related material, components and cabling which are not specified but required to ensure full operation must be supplied by the vendor

Ya

Tidak
12. SUPPORT & WARRANTY -
I. Delivery cost of the equipment is borne by the vendor
Ya

Tidak
II. Must provide comprehensive and extensive after sales service on labor and overall parts

Ya

Tidak
III. All other related software, material, components and cabling which are not specified but are required to ensure full integration of the item MUST be provided.
Ya

Tidak
13. INSTALLATION & TRAINING: -
I. Pre requisite of requirement of installation, testing and commissioning on site for the supplied package and components MUST be done by tenderer
Ya

Tidak
II. Tendered MUST provide Transfer Technology Session (TOT) training for configuration, operation and maintenance of the system which must cover Rack Mountable Base Unit System Intelligent and UPS Management Software for UiTM's personnel.(Plase specify details of the training by providing
syllabus/guideline).
Ya

Tidak
III. Minimum of three (3) participants on Server and System Management training session
Ya

Tidak
IV. Original training materials (hard copy and soft copy) and documentation MUST be provided on the training day.
Ya

Tidak
V. Delivery and installation at site of server as per instruction of UiTM without incurring any additional costs to UiTM.
Ya

Tidak